| Who regulates | <cite index="3-2">The DOH Wastewater Branch runs the IWS application process under Hawaii Administrative Rules, Title 11, Chapter 62</cite>, and the DOH also provides an online filing portal at wastewater.ehawaii.gov. | health.hawaii.gov |
| Approved systems | <cite index="1-3">DOH-approved IWS equipment includes septic tanks, aerobic treatment units, passive aerobic systems that still need a septic tank (e.g., Eljen, Presby), bioreactor gardens, and composting and incinerator toilets</cite>. | health.hawaii.gov |
| Tank standards | <cite index="12-5">Under HAR 11-62-33.1, septic tanks must be approved and listed by IAPMO</cite>, <cite index="12-6">and plans for cast-in-place tanks must be submitted with the IWS application</cite>. | health.hawaii.gov |
| Size and use limits | <cite index="6-2">An IWS is typically required for single-family homes with flows under 1,000 gallons per day</cite>, and DOH land-use comments cite <cite index="10-4">a minimum lot size of 10,000 square feet under Chapter 11-62 to use individual wastewater systems</cite> (this comes from a 2012 DOH comment template, so check the current rule). | health.hawaii.gov |
| Setbacks | <cite index="44-5,44-6">HAR 11-62-32 says no IWS may be closer than the minimum distances in Table II (Appendix D) unless the director approves otherwise, measured from the outer edge of each item</cite>; I could not retrieve the actual Table II distances from an official source, and unofficial sites give conflicting figures (e.g., 50 vs 100 ft to wells), so confirm them with DOH or your engineer. | health.hawaii.gov |
| Pumping/maintenance | <cite index="6-7">DOH says cesspools and septic tanks must be regularly pumped by a registered pumper and hauler to prevent overflows and backups</cite>; I did not find a specific required pumping interval. | health.hawaii.gov |
| Cesspool conversion (Act 125) | <cite index="24-10">Act 125 (2017) requires every cesspool in the state to be upgraded, converted to a septic system, or connected to a sewer by January 1, 2050</cite>. | health.hawaii.gov |
| Cesspool upgrade triggers | <cite index="13-4">A DOH standard comment says that after a significant modification to an existing dwelling, a grandfathered cesspool will have to be upgraded to an IWS such as a septic tank system</cite>, and <cite index="3-7,3-9">DOH treats renovations such as kitchen/bathroom remodels, door/window remodels and adding a bedroom as building renovations in its IWS application scenarios</cite>. | data.capitol.hawaii.gov |
| Sale of property | I found no official state rule requiring a septic inspection or upgrade at sale; DOH only notes that <cite index="6-5">wastewater systems are often neglected or misunderstood when a property is inspected</cite>, and a non-official source says <cite index="24-12">there is no requirement to convert when you sell, though sellers must disclose a cesspool</cite> (verify with a Hawaii real estate attorney or DOH). | health.hawaii.gov |
| Records | <cite index="6-9">You can request records from the Wastewater Branch to see whether it has information on your property's wastewater system</cite>. | health.hawaii.gov |